Width tolerances for cold-rolled copper and copper alloy products (strips), EN 1652
Dimensions in millimetres
Width tolerance for specified widths | ||||||||
|---|---|---|---|---|---|---|---|---|
Specified thickness | over 50 | over 100 | over 200 | over 350 | over 500 | over 700 | ||
| over | up to and including | up to and including 50 | up to and including 100 | up to and including 200 | up to and including 300 | up to and including 500 | up to and including 700 | up to and including 1250 |
| 0,11) | 1.0 | +0,20 | +0,30 | +0,40 | +0,60 | +1,0 | +1,5 | +2,0 |
| 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
| 1.0 | 2.0 | +0,30 | +0,40 | +0,50 | +1,0 | +1,2 | +1,5 | +2,0 |
| 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
| 2.0 | 2.5 | +0,50 | +0,60 | +0,70 | +1,2 | +1,5 | +2,0 | +2,5 |
| 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
| 2.5 | 3.0 | +1,0 | +1,10 | +1,20 | +1,5 | +2,0 | +2,5 | +3,0 |
| 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
| 3.0 | 4.0 | +2,0 | +2,30 | +2,50 | +3,0 | +4,0 | +5,0 | +6,0 |
| 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
| 1) lncluding 0,1. | ||||||||